HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
[PE3-md-md1-ma-ma1] mep ccm-send enable
[PE3-md-md1-ma-ma1] remote-mep ccm-receive enable
[PE3-md-md1-ma-ma1] quit
[PE4-md-md1] quit
# Configure basic CFM functions on PE4.
[PE4] vlan 2
[PE4--vlan2] quit
[PE4] interface GigabitEthernet1/0/2
[PE4-GigabitEthernet1/0/2] portswitch
[PE4-GigabitEthernet1/0/2] port trunk allow-pass vlan 2
[PE4-GigabitEthernet1/0/2] quit
[PE4] cfm md md1
[PE4-md-md1] ma ma1
[PE4-md-md1-ma-ma1] map vlan 2
[PE4-md-md1-ma-ma1] mep mep-id 2 interface GigabitEthernet 1/0/2 outward
[PE4-md-md1-ma-ma1] remote-mep mep-id 1
[PE4-md-md1-ma-ma1] mep ccm-send enable
[PE4-md-md1-ma-ma1] remote-mep ccm-receive enable
[PE4-md-md1-ma-ma1] quit
[PE4-md-md1] quit
# Verify the configuration.
Run the display cfm remote-mep command on PE3 or PE4. If CFM is correctly configured on
PE3 and PE4, the command output shows that the CFM Status field value is Up.
[PE3] display cfm remote-mep
The total number of RMEPs is : 1
The status of RMEPs : 1 up, 0 down, 0 disable
--------------------------------------------------
MD Name
Level
MA Name
RMEP ID
VLAN ID
VSI Name
L2VC ID
MAC
CCM Receive
Trigger-If-Down
CFM Status
Alarm Status
Interface TLV
Connect Status
Step 3 Configure association between EFM and CFM.
# Configure association between EFM and CFM on PE3.
[PE3] oam-mgr
[PE3-oam-mgr] oam-bind cfm md md1 ma ma1 efm interface GigabitEthernet 1/0/1
[PE3-oam-mgr] quit
# Configure association between EFM and CFM on PE4.
[PE4] oam-mgr
[PE4-oam-mgr] oam-bind cfm md md1 ma ma1 efm interface GigabitEthernet 1/0/1
[PE4-oam-mgr] quit
Step 4 Configure association between EFM and interfaces on CE2.
[CE2] interface GigabitEthernet1/0/1
[CE2-GigabitEthernet1/0/1] efm trigger if-down
[CE2-GigabitEthernet1/0/1] quit
Issue 02 (2014-09-30)
: md1
: 0
: ma1
: 2
: 2
: --
: --
: --
: enabled
: disabled
: up
: none
: disabled
: up
Huawei Proprietary and Confidential