# Create an IP-Trunk interface on Router B and set the lower threshold of IP-Trunk member
links in the Up state to 1.
<HUAWEI> system-view
[HUAWEI] sysname RouterB
[RouterB] interface ip-trunk 1
[RouterB-Ip-Trunk1] undo shutdown
[RouterB-Ip-Trunk1] ip address 10.1.1.2 255.255.255.0
[RouterB-Ip-Trunk1] least active-linknumber 1
[RouterB-Ip-Trunk1] quit
[RouterB] interface pos 1/0/0
[RouterB-Pos1/0/0] undo shutdown
[RouterB-Pos1/0/0] link-protocol hdlc
[RouterB-Pos1/0/0] ip-trunk 1
[RouterB-Pos1/0/0] quit
[RouterB] interface pos 2/0/0
[RouterB-Pos2/0/0] undo shutdown
[RouterB-Pos2/0/0] link-protocol hdlc
[RouterB-Pos2/0/0] ip-trunk 1
[RouterB-Pos2/0/0] quit
After the configurations, run the display interface ip-trunk command on Router A or Router
B. You can view that the status of the interface is Up.
Use the display on Router A as an example.
[RouterA] display interface ip-trunk 1
Ip-Trunk1 current state : UP
Line protocol current state : UP
Last line protocol up time: 2007-11-13, 10:18:19
Description : Ip-Trunk1 Interface, Route Port
Route Port,Hash arithmetic : According to flow,Maximal BW: 5G, Current BW: 5G, T,he
Maximum Transmit Unit is 4470
Internet Address is 10.1.1.1/24 Link layer protocol is nonstandard HDLC
Physical is IP_TRUNK
-----------------------------------------------------
PortName
-----------------------------------------------------
Pos1/0/0
Pos2/0/0
-----------------------------------------------------
The Number of Ports in Trunk : 2
The Number of UP Ports in Trunk : 2
The IP-Trunk interface of Router A and the IP-Trunk interface of Router B can ping each other.
Use the display on Router A as an example.
[RouterA] ping 10.1.1.2
PING 10.1.1.2: 56
--- 10.1.1.2 ping statistics ---
Issue 02 (2014-09-30)
Last 300 seconds input rate 0 bits/sec, 0 packets/sec
Last 300 seconds output rate 0 bits/sec, 0 packets/sec
Realtime 0 seconds input rate 0 bits/sec, 0 packets/sec
Realtime 0 seconds output rate 0 bits/sec, 0 packets/sec
Input: 0 packets,0 bytes,
0 errors,0 drops,
Output:0 packets,0 bytes,
0 errors,0 drops
Input bandwidth utilization
Output bandwidth utilization : 0.01%
Status
UP
UP
data bytes, press CTRL_C to break
Reply from 10.1.1.2: bytes=56 Sequence=1 ttl=255 time=220 ms
Reply from 10.1.1.2: bytes=56 Sequence=2 ttl=255 time=30 ms
Reply from 10.1.1.2: bytes=56 Sequence=3 ttl=255 time=10 ms
Reply from 10.1.1.2: bytes=56 Sequence=4 ttl=255 time=30 ms
Reply from 10.1.1.2: bytes=56 Sequence=5 ttl=255 time=40 ms