This task is supported in P2P scenarios.
g.
Run:
remote-mep mep-id mep-id
The remote MEP ID is configured.
h.
Run:
mep ccm-send enable
The CCM transmission function is enabled.
i.
Run:
remote-mep ccm-receive [ mep-id mep-id ] enable
The CCM reception function is enabled.
2.
On the receiving device of a PW where single-ended frame loss measurement will
be implemented, run:
Table 8-22 Configurations for enabling the receive end to receive LMMs
Usage
Step
Scenario
P2P
Non-test instance-based statistics
scenario
Run the loss-measure single-ended receive mep mep-id
command to enable the RMEP to receive LMMs.
Test instance-based statistics
1. Run the test-id test-id command to configure a test instance.
2. Run the loss-measure single-ended receive test-id test-id
command to enable the RMEP to receive LMMs.
P2MP
1. Run the test-id test-id command to configure a test instance for
scenario
a specific RMEP.
2. Run the loss-measure single-ended receive test-id test-id
command to enable the RMEP to receive LMMs.
3.
On the transmitting device of a PW where single-ended frame loss measurement
will be implemented, run:
Table 8-23 Configurations for enabling a MEP to send LMMs
Usage
Step
Scenario
P2P
Run the loss-measure single-ended send mep mep-id [ mac mac-
scenario
address | remote-mep mep-id ] interval { 1000 | 10000 } count
count-value command to enable on-demand single-ended frame
loss measurement on a PW.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.