Creating An Me And Binding It To A Tunnel Interface - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
Function
Performance statistics
Pre-configuration Tasks
Before configuring MPLS-TP OAM for an LSP, complete the following task:
l
l
Data Preparation
To configure MPLS-TP OAM for an LSP, you need the following data.
No.
1
2
3
4
4
5

9.3.2 Creating an ME and Binding It to a Tunnel Interface

This section describes how to create an ME and bind it to a bidirectional LSP.
Issue 02 (2014-09-30)
Application
Scenario
Packet loss statistics LM: checks statistics about packets
Delay and delay
jitter measurement
Configuring a bidirectional LSP
Enabling the packet statistics function on the LSP interfaces
Data
MEG name
Name of the tunnel interface bound to the ME
(Optional) Interval of Continuity Check Message (CCM) transmissions and priority
of CCMs
(Optional) Interval and number of loss measurement message (LMM) transmissions
and priority of LMMs
(Optional) Interval and number of transmissions of delay measurement packets and
priority of the packets
(Optional) Interval between AIS PDU transmissions and priority of AIS PDUs
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 MPLS-TP OAM Configuration
Configuration Procedure
CV: checks whether MEG configurations
on the ingress LER and egress LER of a
bidirectional LSP are consistent and will
report alarms if any inconsistency is
detected.
dropped between the ingress LER and
egress LER of a bidirectional LSP.
DM: checks statistics about the delay and
delay jitter between the ingress LER and
egress LER of a bidirectional LSP.
928