Configuration Guide - Reliability
IP Multihop Destination Port : 3784
Total Up/Down Session Number : 0/1
Current Session Number :
--------------------------------------------------------------------------------
PAF/LCS Name
--------------------------------------------------------------------------------
BFD_CFG_NUM
BFD_IF_NUM
BFD_SESSION_NUM
BFD_IO_SESSION_NUM
BFD_PER_TUNNEL_CFG_NUM
--------------------------------------------------------------------------------
IO Board Current Created Session Statistics Information :(slot/number)
--------------------------------------------------------------------------------
0 /0
8 /0
16/0
24/0
32/0
--------------------------------------------------------------------------------
Current Total Used Discriminator Num
--------------------------------------------------------------------------------
IO Board Reserved Sessions Number Information :(slot/number)
--------------------------------------------------------------------------------
0 /0
8 /0
16/0
24/0
32/0
--------------------------------------------------------------------------------
BFD HA Information :
--------------------------------------------------------------------------------
Core Current HA Status
Shell Current HA Status
--------------------------------------------------------------------------------
BFD for LSP Information :
--------------------------------------------------------------------------------
Ability of auto creating BFD session on egress
Period of LSP Ping
System Session Delay Up Timer
--------------------------------------------------------------------------------
5.10 Configuring a BFD Session with the One-Arm Echo
Function
By configuring a BFD session with the one-arm Echo function, you can fast detect and monitor
a direct link between a BFD-capable device and a BFD-incapable device.

5.10.1 Before You Start

Before configuring the BFD session with the one-arm Echo function, familiarize yourself with
the usage scenario, complete the pre-configuration tasks, and obtain the required data.
Issue 02 (2014-09-30)
Static session
: 0
E_Dynamic session
: 0
LDP_LSP session
: 0
TE_TUNNEL session
: 0
PW session
: 0
1 /0
2 /1
9 /0
10/0
17/0
18/0
25/0
26/0
33/0
34/0
1 /0
2 /0
9 /0
10/0
17/0
18/0
25/0
26/0
33/0
34/0
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Dynamic session
STATIC_AUTO session
STATIC_LSP session
TE_LSP session
IP session
Maxnum
8192
512
8192
512
16
3 /0
4 /0
5 /0
11/0
12/0
13/0
19/0
20/0
21/0
27/0
28/0
29/0
35/0
36/0
37/0
3 /0
4 /0
5 /0
11/0
12/0
13/0
19/0
20/0
21/0
27/0
28/0
29/0
35/0
36/0
37/0
: OFF
5 BFD Configuration
: 0
: 1
: 0
: 0
: 1
Minnum
Create
1
1
1
1
1
1
1
0
1
0
6 /0
7 /0
14/0
15/0
22/0
23/0
30/0
31/0
: 1
6 /0
7 /0
14/0
15/0
22/0
23/0
30/0
31/0
: Normal
: Normal
: Disable
: 60
348