Data Preparation
To configure the system-level GR, you need the following data.
No.
1

6.2.2 (Optional) Configuring the Default Slot Number for the SMB

You can set the slot ID of the default SMB for the system restart.
Context
If both main boards are available, the system determines which one is to be the SMB when the
router restarts. Set the default slot number of the SMB using the command mentioned in this
section.
Perform the following steps on the GR Restarter:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
slave default slot-id
The default slot number for the SMB is configured.
----End
6.2.3 Enabling the Automatic Synchronization of the AMB/SMB
Configuration
You can enable the SMB to automatically synchronize configurations with the AMB when the
AMB is writing the configurations.
Context
Perform the following steps on the GR Restarter:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Issue 02 (2014-09-30)