HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
Interface
----------------------------------------------------------------------
GigabitEthernet1/0/2
Step 2 Configure remote loopback.
# Configure remote loopback on CE1.
[CE1] interface gigabitethernet 1/0/2
[CE1-GigabitEthernet1/0/2] efm loopback start
[CE1-GigabitEthernet1/0/2] quit
Verify the configuration.
After configuring remote loopback, run the display efm session { all | interface interface-
type interface-num } command on CE1. The command output shows that the EFM status is
Loopback (control) on GE 2/0/1.
[CE1] display efm session interface gigabitethernet 1/0/2
----------------------------------------------------------------------
Run the display efm session { all | interface interface-type interface-num } command on CE4.
The command output shows that the EFM status is Loopback (be controlled) on GE 2/0/1.
[CE4] display efm session interface gigabitethernet 2/0/1
Interface
----------------------------------------------------------------------
GigabitEthernet1/0/0
Step 3 Configure CE1 to send test packets to CE4.
[CE1] test-packet start interface gigabitethernet 1/0/2
Step 4 Check returned test packets on CE1.
[CE1] display test-packet result
TestResult
--------------------------------------------------------
PacketsSend
PacketsReceive :
PacketsLost
BytesSend
BytesReceive
BytesLost
StartTime
EndTime
Link quality can be evaluated based on data in the preceding command output.
Step 5 Disable remote loopback.
[CE1] interface gigabitethernet 1/0/2
[CE1-GigabitEthernet1/0/2] efm loopback stop
[CE1-GigabitEthernet1/0/2] quit
Step 6 Verify the configuration.
After disabling remote loopback, run the display efm session { all | interface interface-type
interface-num } command on CE1 or CE4. The command output shows that the EFM status is
Detect or Discovery on the interfaces at both ends of the link. For example:
Issue 02 (2014-09-30)
Interface
GigabitEthernet1/0/2
Value
:
0
0
:
0
:
0
:
0
:
0
:
00-00-0000 00:00:00 UTC+00:00
:
00-00-0000 00:00:00 UTC+00:00
NOTE
The default timeout period of remote loopback is 20 minutes. After the timeout period expires, remote
loopback is automatically disabled. To disable remote loopback, perform the preceding step.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
EFM State
detect
EFM State
loopback (control)
EFM State
loopback (be controlled)
8 Ethernet OAM Configuration
Loopback Timeout
--
Loopback Timeout
20
Loopback Timeout
--
675