Huawei NetEngine80E Configuration Manual - Reliability page 788

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
<HUAWEI> display y1731 statistic-type single-loss md md1 ma ma1 peer-ip 2.2.2.2
Latest single-ended loss statistics:
--------------------------------------------------------------------------------
Index
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Average Local-loss
Maximum Local-loss
Minimum Local-loss
Average Remote-loss :
Maximum Remote-loss :
Minimum Remote-loss :
<HUAWEI> display y1731 statistic-type single-loss test-id 1
Latest single-ended loss statistics of 802.1p 1:
--------------------------------------------------------------------------------
Index
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Average Local-loss
Maximum Local-loss
Minimum Local-loss
Average Remote-loss :
Maximum Remote-loss :
Minimum Remote-loss :
Configuring Dual-ended Frame Loss Measurement in VPLS Networking
In VPLS networking, CFM is enabled to monitor link connectivity. if accurate frame loss
measurement needs to be performed for a link, dual-ended frame loss measurement can be
configured to monitor the quality of the link.
Context
Dual-ended frame loss measurement in VPLS networking is carried out continuously to permit
proactive reporting of frame loss or performance results. Dual-ended frame loss measurement
in VPLS networking is usually deployed on end-to-end MEPs. Frame loss statistics are collected
based on the transmit and receive counters carried by CCMs. Dual-ended frame loss
measurement can be successfully performed only when the remote MEP is in the Up state.
Procedure
l
Issue 02 (2014-09-30)
Local-loss
Local-loss ratio
1
20
2
20
3
20
4
20
5
20
6
20
7
20
8
20
9
20
10
20
11
20
12
20
13
20
14
20
:
:
:
Local-loss
Local-loss ratio
1
0
:
:
:
Configure dual-ended frame loss measurement for a PW.
NOTE
Perform the following steps on the devices initiates dual-ended frame loss measurement.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Remote-loss
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
50.0000%
20
Average Local-loss Ratio
20
Maximum Local-loss Ratio
20
Minimum Local-loss Ratio
30
Average Remote-loss Ratio :
30
Maximum Remote-loss Ratio :
30
Minimum Remote-loss Ratio :
Remote-loss
0.0000%
0
Average Local-loss Ratio
0
Maximum Local-loss Ratio
0
Minimum Local-loss Ratio
0
Average Remote-loss Ratio :
0
Maximum Remote-loss Ratio :
0
Minimum Remote-loss Ratio :
8 Ethernet OAM Configuration
Remote-loss ratio
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
30
75.0000%
:
50.0000%
:
50.0000%
:
50.0000%
75.0000%
75.0000%
75.0000%
Remote-loss ratio
0
0.0000%
:
0.0000%
:
0.0000%
:
0.0000%
0.0000%
0.0000%
0.0000%
771