Switching IEEE 802.1ag Versions
A device can switch its Ethernet CFM version between IEEE 802.1ag Draft 7 and IEEE Standard
802.1ag-2007.
Context
By default, IEEE 802.1ag Draft 7 is enabled on the device. Perform the following steps on each
NE80E/40E that requires IEEE Standard 802.1ag-2007:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
cfm version { draft7 | standard }
The IEEE 802.1ag version is switched.
----End
Enabling Ethernet CFM Globally
You must enable Ethernet CFM globally before configuring and applying all CFM functions.
Context
Perform the following steps on the router that requires Ethernet CFM:
Procedure
Step 1 Run:
system-view
Issue 02 (2014-09-30)
Data
(Optional) ID of an RMEP and MAC address of the interface where the RMEP resides
Rule for creating a MIP
Interval for a MEP sending or detecting CCMs in an MA
(Optional) ID of the specified VLAN
NOTE
All the devices on the network must be enabled with either IEEE 802.1ag Draft 7 or IEEE Standard
802.1ag-2007. IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007 cannot be enabled at the same time
on a network.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.