Huawei Quidway S3700 Series Configuration Manual page 291

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
Step 2 Configure basic Ethernet CFM functions.
# Configure Switch A.
[SwitchA] cfm version standard
[SwitchA] cfm enable
[SwitchA] cfm md md1
[SwitchA-md-md1] ma ma1
[SwitchA-md-md1-ma-ma1] map vlan 2
[SwitchA-md-md1-ma-ma1] quit
[SwitchA-md-md1] quit
# Configure Switch B.
[SwitchB] cfm version standard
[SwitchB] cfm enable
[SwitchB] cfm md md1
[SwitchB-md-md1] ma ma1
[SwitchB-md-md1-ma-ma1] map vlan 2
[SwitchB-md-md1-ma-ma1] quit
[SwitchB-md-md1] quit
Step 3 Configure outward-facing MEPs.
# Configure Switch A.
[SwitchA] cfm md md1
[SwitchA-md-md1] ma ma1
[SwitchA-md-md1-ma-ma1] mep mep-id 1 interface ethernet 0/0/1 outward
[SwitchA-md-md1-ma-ma1] remote-mep mep-id 2
[SwitchA-md-md1-ma-ma1] mep ccm-send mep-id 1 enable
[SwitchA-md-md1-ma-ma1] remote-mep ccm-receive mep-id 2 enable
[SwitchA-md-md1-ma-ma1] quit
[SwitchA-md-md1] quit
# Configure Switch B.
[SwitchB] cfm md md1
[SwitchB-md-md1] ma ma1
[SwitchB-md-md1-ma-ma1] mep mep-id 2 interface ethernet 0/0/1 outward
[SwitchB-md-md1-ma-ma1] remote-mep mep-id 1
[SwitchB-md-md1-ma-ma1] mep ccm-send mep-id 2 enable
[SwitchA-md-md1-ma-ma1] remote-mep ccm-receive mep-id 1 enable
[SwitchB-md-md1-ma-ma1] quit
[SwitchB-md-md1] quit
Step 4 Set the alarm threshold for the two-way frame delay measurement to 1000.
# Configure Switch A.
[SwitchA] cfm md md1
[SwitchA-md-md1] ma ma1
[SwitchA-md-md1-ma-ma1] delay-measure two-way threshold 1000
[SwitchA-md-md1-ma-ma1] quit
[SwitchA-md-md1] quit
# Configure Switch B.
[SwitchB] cfm md md1
[SwitchB-md-md1] ma ma1
[SwitchB-md-md1-ma-ma1] delay-measure two-way threshold 1000
[SwitchB-md-md1-ma-ma1] quit
[SwitchB-md-md1] quit
Step 5 Configure the two-way frame delay measurement in a VLAN.
# Configure Switch A.
[SwitchA] cfm md md1
[SwitchA-md-md1] ma ma1
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 ITU-T Recommendation Y.1731 Configuration
279

Advertisement

Table of Contents
loading

Table of Contents