Checking The Configuration; Associating Efm Oam With Ethernet Cfm - Huawei Quidway S3700 Series Configuration Manual

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
Scenario
Fault
information
needs to be
transmitted
unidirection
ally between
Ethernet
CFM and an
interface.
----End

4.13.3 Checking the Configuration

After the association between Ethernet CFM and an interface is successfully configured, you
can view the related association configuration in the OAM management view.
Prerequisite
All configurations of the association between Ethernet CFM and an interface are complete.
Procedure
Step 1 Run the display this command in the OAM management view to check whether Ethernet CFM
and an interface are successfully associated.
----End
Example
Run the display this command. You can view all associations between Ethernet CFM and
interfaces.
[Quidway-oam-mgr] display this
#
oam-mgr
oam-bind ingress interface Ethernet0/0/1 egress cfm md md1 ma ma1 trigger if-down
oam-bind ingress cfm md md1 ma ma1 trigger if-down egress interface Ethernet0/0/2
#
return

4.14 Associating EFM OAM with Ethernet CFM

This section describes how to associate EFM OAM with Ethernet CFM.
Issue 01 (2011-10-26)
Configuration Scheme 1
Choose either of the following
commands according to the
transmission direction:
l If fault information needs to be
transmitted from Ethernet CFM to
the interface, use the following
command:
oam-bind ingress cfm md ma
egress interface
l If fault information needs to be
transmitted from the interface to
Ethernet CFM, use the following
command:
oam-bind ingress interface egress
cfm md ma trigger if-down
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration
Configuration Scheme 2
None
203

Advertisement

Table of Contents
loading

Table of Contents