Configuring Association Between Ethernet Cfm And Sep; Checking The Configuration - Huawei Quidway S3700 Series Configuration Manual

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
No.
2
3
4

4.16.2 Configuring Association Between Ethernet CFM and SEP

Context
Do as follows on the device where association between Ethernet CFM and SEP needs to be
configured.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
oam-mgr
The OAM management view is displayed.
Step 3 Run:
oam-bind ingress cfm md md-name ma ma-name egress sep segment segment-id interface
interface-type interface-number
Association between Ethernet CFM and SEP is configured.
The interface specified by interface interface-type interface-number must be added to the SEP
segment.
----End

4.16.3 Checking the Configuration

Prerequisite
The configurations of association between Ethernet CFM and SEP are complete.
Procedure
Step 1 Run the display this command in the OAM management view to check association between
Ethernet CFM and SEP.
[Quidway-oam-mgr] display this
#
oam-mgr
oam-bind ingress cfm md md1 ma ma1 egress sep segment 1 interface Ethernet0/0/1
#
----End
Issue 01 (2011-10-26)
Data
Names of MDs and MAs
SEP segment
Number of the interface added to the SEP segment
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration
209

Advertisement

Table of Contents
loading