Associating Efm Oam With An Interface - Huawei Quidway S3700 Series Configuration Manual

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
Pre-configuration Tasks
Before associating EFM OAM with an interface, complete the following tasks:
l
Data Preparation
To associate EFM OAM with an interface, you need the following data.
No.
1
2

4.6.2 Associating EFM OAM with an Interface

By associating EFM OAM with a physical interface, you can use the OAM management module
to notify the bound interface management module of fault information after EFM OAM detects
a fault.
Context
After EFM OAM is enabled on an interface, the status of this interface changes when the interface
receives an OAM PDU control request packet with the Link Fault Status flag.
There are two ways to associate EFM OAM with an interface:
l
l
l
Do as follows on the devices at one end or both ends of the link:
Procedure
l
Issue 01 (2011-10-26)
Configuring EFM OAM
Data
Type and number of an interface
(Optional) Faulty-state hold timer
Associating an error event with an interface and setting the interface to the blocking state
when the error event occurs.
Associating an error event with an interface and setting the interface to the disabled state
when the error event occurs.
Associating a threshold crossing event with an interface.
Associate an error event with an interface and set the interface to the blocking state when
the error event occurs.
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface interface-type interface-number
The view of an interface at one end of the link is displayed.
3.
Run:
efm trigger if-down
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration
169

Advertisement

Table of Contents
loading

Table of Contents