Huawei Quidway S3700 Series Configuration Manual page 164

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
Table 4-1 Differences between IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007
Feature
MD
Default MD
MA
MEP
RMEP
MIP
MP
l
Issue 01 (2011-10-26)
draft7
Supported
Not supported
Supported
Supported
Supported
Supported
Supported
Terms
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration
standard2007
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Remarks
The features and
configurations supported
by 802.1ag Draft 7 and
Standard 802.1ag-2007 are
the same.
-
The features and
configurations supported
by 802.1ag Draft 7 and
Standard 802.1ag-2007 are
the same.
The features and
configurations supported
by 802.1ag Draft 7 and
Standard 802.1ag-2007 are
the same.
The features and
configurations supported
by 802.1ag Draft 7 and
Standard 802.1ag-2007 are
the same.
802.1ag Draft 7 and
Standard 802.1ag-2007
contain the same types of
MIP creation rules, that is,
default, explicit, and none.
The differences are as
follows:
l In 802.1ag Draft 7, MIPs
are created based on the
interface.
l In Standard
802.1ag-2007, MIPs are
created based on the MD
or default MD.
The features and
configurations supported
by 802.1ag Draft 7 and
Standard 802.1ag-2007 are
the same.
152