On UPEA or PE-AGG, run the display cfm remote-mep command to check the status of
Ethernet CFM. You can find that Ethernet CFM is in Up state. Take the display on PE-AGG as
an example.
[PE-AGG] display cfm remote-mep
The total number of RMEPs is : 2
--------------------------------------------------
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
MAC
CCM Receive
Trigger-If-Down
CFM Status
Alarm Status
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
MAC
CCM Receive
Trigger-If-Down
CFM Status
Alarm Status
Step 7 Configure the association between Ethernet CFM and interfaces.
# Configure PE-AGG.
[PE-AGG] oam-mgr
[PE-AGG-oam-mgr] oam-bind cfm md md1 ma ma1 trigger if-down interface ethernet
0/0/1
[PE-AGG-oam-mgr] oam-bind cfm md md1 ma ma2 trigger if-down interface ethernet
0/0/2
[PE-AGG-oam-mgr] quit
Step 8 Verify the configuration.
Shut down Eth 0/0/1 on UPEB and simulate fault on the link of Eth 0/0/1and run the display
cfm remote-mep command on PE-AGG to check the CFM status. The following information
is displayed:
[PE-AGG] display cfm remote-mep
The total number of RMEPs is : 2
--------------------------------------------------
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
MAC
CCM Receive
Trigger-If-Down
CFM Status
Alarm Status
MD Name
Level
MA Name
RMEP ID
Vlan ID
Issue 01 (2011-10-26)
: md1
: 0
: ma1
: 1
: 100
: --
: --
: enabled
: disabled
: up
: RemoteAlarms
: md1
: 0
: ma2
: 3
: 100
: --
: --
: enabled
: disabled
: up
: RemoteAlarms
: md1
: 0
: ma1
: 1
: 100
: --
: --
: enabled
: disabled
: down
: RemoteAlarms
: md1
: 0
: ma2
: 3
: 100