Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
Figure 4-9 Networking diagram of the association between Ethernet CFM and an interface
CE1
If the bidirectional association between Ethernet CFM and an interface is configured on PE2,
the OAM management module sends fault information to Ethernet CFM associated with GE
0/0/2 when GE 0/0/2 goes Down on PE2 connected to CE2. Ethernet CFM messages carrying
fault information are sent to the OAM module on PE1, which triggers the physical status of
GE 0/0/2 on PE1 to become Down. CE1 can then detect the fault and switch traffic to a backup
path, which ensures reliable service transmission.
Pre-configuration Tasks
Before configuring the association between Ethernet CFM and an interface (in the OAM
management view), complete the following task:
l
Data Preparation
To configure the association between Ethernet CFM and an interface (in the OAM management
view), you need the following data.
No.
1
2
3
4.13.2 Configuring Association Between Ethernet CFM and an
Interface
Ethernet CFM can be associated with only one interface. When Ethernet CFM is associated with
an interface, it cannot be associated with another interface. In addition, the interface cannot be
associated with Ethernet CFM on another device.
Issue 01 (2011-10-26)
PE1
Ethernet CFM
GE0/0/1
GE0/0/2
Interface associated with Ethernet CFM
Interface enabled with Ethernet CFM
Configuring Basic Ethernet CFM Functions
Data
Type and number of each interface associated with Ethernet CFM
Type and number of each interface enabled with Ethernet CFM
Name of an MD and MA

Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.
PE2
GE0/0/1
GE0/0/2
CE2
4 Ethernet OAM Configuration