Creating The Rrpp Domain - Huawei Quidway S3700 Series Configuration Manual

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
Step 2 Run:
interface interface-type interface-number
The interface view is displayed.
RRPP rings can be configured only on Ethernet interfaces, GE interfaces, and Eth-Trunk
interfaces.
An interface cannot be configured as an RRPP interface if the Smart Link, LDT, MUX VLAN
or MSTP is configured on the interface.
Step 3 (Optional) Run:
port link-type trunk
The interface is configured as a trunk interface.
By default, an interface is a hybrid interface.
An RRPP interface needs to allow packets of control VLANs and data VLANs to pass through;
therefore, the RRPP interface must be configured as a trunk interface or hybrid interface.
Step 4 Run:
port trunk allow-pass vlan { { vlan-id1 [ to vlan-id2 ] } &<1-10> | all }
or run:
port hybrid tagged vlan { { vlan-id1 [ to vlan-id2
IDs of the data VLANs whose packets are allowed to pass through the RRPP interface are
specified.
After you specify the control VLAN by running the control-vlan command in the RRPP domain
view and run the ring node-mode command, all the interfaces on the RRPP ring allow packets
of this control VLAN to pass through. Therefore, you need only to specify the data VLANs in
this step.
Step 5 Run:
stp disable
STP is disabled on the RRPP interface.
By default, STP is enabled on all interfaces of the S3700. Before creating an RRPP ring, disable
STP on the interfaces that need to be added to the RRPP ring.
----End

3.3.4 Creating the RRPP Domain

A group of connected switches that have the same domain ID and the same control VLANs
constitute an RRPP domain. An RRPP domain mainly consists of RRPP rings, control VLANs,
and master nodes.
Context
Do as follows on all switches in the RRPP domain:
Procedure
Step 1 Run:
system-view
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 RRPP Configuration
] }&<1-10> | all }
55

Advertisement

Table of Contents
loading

Table of Contents