4.18.2 Example for Testing the Packet Loss Ratio on a Link

Networking Requirements
As shown in
Switch B. Switch A functions as the CE device, and Switch B functions as the UPE device. The
link between Switch A and Switch B is newly established. The ISP needs to test the packet loss
ratio on the link on Switch B before using the link.
Issue 01 (2011-10-26)
ErrFrameSecondPeriod:
ErrFrameSecondThreshold:
Hold Up Time:
ThresholdEvtTriggerErrDown:
TriggerIfDown:
TriggerMacRenew:
Remote MAC:
Remote EFM Enable Flag:
Remote Mode:
Remote
MaxSize:
Remote State:
Configuration file of Switch A
#
sysname SwitchA
#
efm enable
#
interface Ethernet0/0/1
efm mode passive
efm enable
#
return
Configuration file of Switch B
#
sysname SwitchB
#
efm enable
#
interface Ethernet0/0/1
efm enable
efm error-frame period 5
efm error-frame threshold 5
efm error-frame notification enable
efm error-frame-second period 120
efm error-frame-second threshold 5
efm error-frame-second notification enable
efm error-code period 5
efm error-code threshold 5
efm error-code notification enable
#
return
Figure
4-13, a user network is connected to an ISP network through Switch A and
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
120
5
10
enable
disable
disable
0010-0010-0010
enable
passive
128
--
4 Ethernet OAM Configuration
213

Advertisement

Table of Contents
loading

Table of Contents