[SwitchB] oam-mgr
[SwitchB-oam-mgr] oam-bind cfm md md1 ma ma1 cfm md md1 ma ma2
[SwitchB-oam-mgr] quit
Step 5 Verify the configuration.
Shut down Eth 0/0/2 of Switch B. Run the display cfm remote-mep command on Switch A to
check the CFM status between Switch A and Switch B, and you can find that the CFM status is
Down.
[SwitchA]display
The total number of RMEPs is : 1
--------------------------------------------------
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
MAC
CCM Receive
Trigger-If-Down
CFM Status
Alarm Status
----End
Configuration Files
l
l
Issue 01 (2011-10-26)
cfm remote-mep
: md1
: 0
: ma1
: 2
: 10
: --
: --
: enabled
: disabled
: down
: RemoteAlarms
Configuration file of Switch A
#
sysname SwitchA
#
vlan batch 10
#
cfm enable
#
interface Ethernet0/0/1
port link-type trunk
port trunk allow-pass vlan 10
#
cfm md md1
ma ma1
map vlan 10
mep mep-id 1 interface Ethernet0/0/1 outward
mep ccm-send mep-id 1 enable
remote-mep mep-id 2
remote-mep ccm-receive mep-id 2 enable
#
return
Configuration file of Switch B
#
sysname SwitchB
#
vlan batch 10 20
#
cfm enable
#
interface Ethernet0/0/1
port link-type trunk
port trunk allow-pass vlan 10
#
interface Ethernet0/0/2
port link-type trunk
port trunk allow-pass vlan 20
#