Huawei Quidway S3700 Series Configuration Manual page 232

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
[SwitchG-md-md1-ma-ma2] remote-mep mep-id 1
[SwitchG-md-md1-ma-ma2] quit
[SwitchG-md-md1] quit
Step 8 Create MEPs and RMEPs in MA 3 of MD 2 on Switch A, Switch C, and Switch D.
# Create a MEP in MA 3 of MD 2 on Switch A.
[SwitchA] cfm md md2
[SwitchA-md-md2] ma ma3
[SwitchA-md-md2-ma-ma3] mep mep-id 1 interface ethernet 0/0/3 inward
# Create a MEP in MA 3 of MD 2 on Switch C.
<Quidway> system-view
[Quidway] sysname SwitchC
[SwitchC] cfm md md2
[SwitchC-md-md2] ma ma3
[SwitchC-md-md2-ma-ma3] mep mep-id 2 interface ethernet 0/0/3 outward
# Create a MEP in MA 3 of MD 2 on Switch D.
<Quidway> system-view
[Quidway] sysname SwitchD
[SwitchD] cfm md md2
[SwitchD-md-md2] ma ma3
[SwitchD-md-md2-ma-ma3] mep mep-id 3 interface ethernet 0/0/3 inward
# Create an RMEP in MA 3 of MD 2 on Switch A.
[SwitchA-md-md2-ma-ma3] remote-mep mep-id 2
[SwitchA-md-md2-ma-ma3] remote-mep mep-id 3
# Create an RMEP in MA 3 of MD 2 on Switch C.
[SwitchC-md-md2-ma-ma3] remote-mep mep-id 1
[SwitchC-md-md2-ma-ma3] remote-mep mep-id 3
[SwitchC-md-md2-ma-ma3] quit
[SwitchC-md-md2] quit
# Create an RMEP in MA 3 of MD 2 on Switch D.
[SwitchD-md-md2-ma-ma3] remote-mep mep-id 1
[SwitchD-md-md2-ma-ma3] remote-mep mep-id 2
[SwitchD-md-md2-ma-ma3] quit
[SwitchD-md-md2] quit
Step 9 Enable sending and receiving of CCMs.
# Enable Switch A to send CCMs of all the MEPs.
[SwitchA-md-md2-ma-ma3] mep ccm-send enable
# Enable Switch A to receive CCMs sent from all the RMEPs.
[SwitchA-md-md2-ma-ma3] remote-mep ccm-receive enable
[SwitchA-md-md2-ma-ma3] quit
[SwitchA-md-md2] quit
# Enable sending and receiving of CCMs on Switches B to I.
The configurations of these Switches are similar to the configuration of Switch A, and are not
mentioned here.
Step 10 Verify the configuration.
Run the display cfm remote-mep command to view detailed information about the RMEP. You
can view the RMEP status and check whether the CFM configuration is successful.
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration
220

Advertisement

Table of Contents
loading

Table of Contents