Data Preparation
To configure the one-way delay measurement in the VLAN, you need the following data:
No.
1
2
3
4

5.3.2 Binding an MA to a VLAN

Binding an MA to a VLAN is a prerequisite for configuring the one-way frame delay
measurement in the VLAN.
Context
Do as follows on the devices configured with MEPs:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
cfm version { draft7 | standard }
The 802.1ag version is set to IEEE Standard 802.1ag-2007.
After the version is changed, all CFM configurations are deleted; therefore, use the cfm version
command with caution.
Step 3 Run:
cfm md md-name
Issue 01 (2011-10-26)
Configuring VLAN, For the configuration procedure, see VLAN Configuration
4.8 Configuring Basic Ethernet CFM
Data
Names of the MD and MA
ID of the MEP, name of the interface on which the MEP resides, and type of the MEP
Name of the VLAN bound to the MA
(Optional) Alarm threshold of the one-way frame delay measurement
NOTE
IEEE 802.1ag has two versions: IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007. Y.1731 can be
used only on the device complying with IEEE Standard 802.1ag-2007. Therefore, run the cfm version
command to set the 802.1ag version to IEEE Standard 802.1ag-2007 before configuring Y.1731.
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 ITU-T Recommendation Y.1731 Configuration
264

Advertisement

Table of Contents
loading

Table of Contents