Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
rrpp domain domain-id
The RRPP domain view is displayed.
Step 3 Run:
ring ring-id node-mode { master | transit } primary-port interface-type interface-
number secondary-port interface-type interface-number level level-value
An RRPP ring is created.
RRPP rings can be configured only on Ethernet interfaces, GE interfaces, and Eth-Trunk
interfaces.
The level 0 indicates the major ring, and the level 1 indicates the subring.
A domain can contain only one major ring. Before creating a subring, you must create the major
ring.
The master node on a subring cannot function as an edge node or an assistant edge node.
An S3700EI supports 16 rings.
Step 4 Run:
ring ring-id node-mode { edge | assistant-edge } common-port interface-type
interface-number edge-port interface-type interface-number
The edge node and assistant edge node of a subring are configured.
The common port of the edge node and assistant edge node must be on the major ring.
The system automatically sets the level of the ring where the edge node and assistant edge node
reside to 1.
----End

3.3.8 Enabling the RRPP Ring

The protocol packets of sub-rings are transmitted on the major ring as data packets; the protocol
packets of the major ring are transmitted on only the major ring. An RRPP ring can take effect
only when it is enabled.
Context
Do as follows on all switches in the RRPP domain:
Procedure
Step 1 Run:
Issue 01 (2011-10-26)
NOTE
The RRPP ring can be activated only when both the RRPP ring and RRPP protocol are enabled.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 RRPP Configuration