Checking The Configuration; Configuring Basic Ethernet Cfm; Establishing The Configuration Task - Huawei Quidway S3700 Series Configuration Manual

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
interface interface-type2 interface-number2 specifies the interface associated with the EFM
OAM session.
----End

4.7.3 Checking the Configuration

After the association between an EFM OAM session and an interface is successfully configured,
you can view the association configuration in the OAM management view.
Prerequisite
All configurations of the association between an EFM OAM session and an interface are
complete.
Procedure
Step 1 Run the display this command in the OAM management view to check whether an EFM OAM
session and an interface are successfully associated.
----End
Example
Run the display this command. You can view all associations between EFM OAM sessions and
interfaces.
[Quidway-oam-mgr] display this
#
oam-mgr
oam-bind ingress interface GigabitEthernet0/0/1 egress efm interface
GigabitEthernet0/0/2 trigger if-down
oam-bind ingress efm interface GigabitEthernet0/0/2 trigger if-down egress
interface GigabitEthernet0/0/1
#
return

4.8 Configuring Basic Ethernet CFM

By configuring basic Ethernet CFM functions, you can implement end-to-end detection,
advertisement, verification, and location of connectivity faults.

4.8.1 Establishing the Configuration Task

Before configuring basic Ethernet CFM functions, familiarize yourself with the applicable
environment, complete the pre-configuration tasks, and obtain the required data. This can help
you complete the configuration task quickly and accurately.
Issue 01 (2011-10-26)
NOTE
If Step 5 is performed, both the oam-bind ingress efm interface md-name ma ma-name trigger if-
down egress interface interface-type interface-number command and the oam-bind ingress interface
interface-type interface-number egress cfm md md-name ma ma-name trigger if-down command are
displayed in the configuration file, indicating fault notification in opposite directions.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration
175