Multi-function
contact input

Limiting Motor Rotation Direction

If you set motor reverse rotation prohibited, a reverse run command will not be accepted even if it is input.
Use this setting for applications in which reverse motor rotation can cause problems (e.g., fans, pumps, etc.)
Related Parameters
Parameter
Number
Reverse
Operation
b1-04
Selection
Reverse Oper
-56
6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Branch resistance
18 kΩ
PTC thermistor
Fig 6.41 Mutual Connections During Motor Overheating Protection
Name
Description
Display
Determines the forward rotation
of the motor, and if reverse
operation is disabled.
0: Reverse enabled.
1: Reverse disabled.
Drive
Change
Setting
Factory
during
Range
Setting
Operation
0 to 1
0
No
Multi-function
contact output
Fault contact
output
P3
Multi-function
PHC output
C3
P4
C4