Honda NC700XA Service Manual page 694

Hide thumbs Also See for NC700XA:
Table of Contents

Advertisement

dummyhead
dummyhead
ABS INDICATOR STAYS ON (Indicator
does not go off when the motorcycle is
running, Problem code is not indicated
by the retrieval procedure)
1. Service Check Line Short Circuit Inspection
Disconnect the ABS modulator 25P connector [1].
Check for continuity between the ABS modulator
25P connector of the wire harness side and ground.
Connection: Brown – Ground
TOOL:
Test probe
Is there continuity?
YES
NO
2. Indicator Operation Inspection
With
combination meter 16P (Gray) connector [1] of the
wire harness side and ground with a jumper wire [2].
Connection: Orange/black – Ground
Turn the ignition switch ON and engine stop switch
to " ".
Check the ABS indicator.
Does it go off?
YES
NO
3. Indicator Signal Line Open Circuit Inspection
Turn the ignition switch OFF.
Remove the jumper wire from the combination
meter 16P (Gray) connector.
Short the ABS modulator 25P connector [1] of the
wire harness side and ground with a jumper wire [2].
Connection: Orange/black – Ground
TOOL:
Test probe
Turn the ignition switch ON and engine stop switch
to " ".
Check the ABS indicator.
Does it go off?
YES
NO
07ZAJ-RDJA110
– Short circuit in Brown wire
– GO TO STEP 2.
the
connector
connected,
– GO TO STEP 3.
– Faulty combination meter
07ZAJ-RDJA110
– GO TO STEP 4.
– Open circuit in Orange/black wire
ANTI-LOCK BRAKE SYSTEM (ABS)
short
the
[2]
[1]
[1]
Br
[1]
O/Bl
O/Bl
[2]
20-13