Saving Settings and Exiting the F160
2-3-6-2
Starting Inspections
2-4
Saving Settings and Exiting the F160
Precaution
44
1.
Press the TRIG Key on the Console or turn ON the STEP signal.
0.Scn 0
RUN
S+ENT:Help S+→:Adjust
S+ESC:Set disp
STEP/TRG:Msr S+↑ ↓:Mem img
SHIFT + TRIG Keys: Re-execute measurement for the displayed im-
age (for freeze and stored images only.)
SHIFT + ENT Keys: Display help messages.
SHIFT + Right Keys: Go to Adjustment Screen.
SHIFT + ESC Keys: Display screen setting menus.
SHIFT + Up/Down Keys: Display stored images.
One measurement will be performed.
0.Scn 0
RUN
OK
OK
OK
OK
1-OK
S+ENT:Help S+→:Adjust
S+ESC:Set disp
STEP/TRG:Msr S+↑ ↓:Mem img
Save settings to flash memory before turning the power OFF.
Flash memory data is loaded each time the F160 is started. Therefore, when
settings have been changed, be sure to save them to flash memory before
turning OFF the power. If the power is turned OFF without saving new set-
tings, all of the setting changes will be lost. Stored images cannot be saved to
flash memory, so all stored images will be cleared when the power is turned
OFF. If you want to keep stored images, backup the images to a personal
computer or Memory Card. Refer to page 78.
1.
Display the Basic Screen for Monitor Mode or Run Mode.
0.Scn 0
MON
2.
Move the cursor to MON (or RUN) and press the ENT Key.
----
---ms
Freeze
NG
63ms
OK
NG
2-OK
Freeze
----
---ms
Section 2-4