Linear Output - Omron ZX Series Operation Manual

Smart sensors
Hide thumbs Also See for ZX Series:
Table of Contents

Advertisement

Settings Required before Application
1-6-3

Linear Output

The default linear output settings are listed in the following table. These
settings are set at the factory and also after initializing the settings.
Default linear
output setting
Voltage
±
output
Current
4 to 20
output
mA
Use the monitor focus function when setting the output voltage to 0 to 5 V
or 1 to 5 V instead of
Example: Setting Linear Output to 0 to 5 V
1. Set the mode switch to FUN.
2. Use the LEFT/RIGHT Keys to display
3. Use the UP/DOWN Keys to change
press the ENT Key to confirm the selection.
4. Use the LEFT/RIGHT Keys to display
Operation after setting reference incident level
Incident level
4 V
display
Intercepted
amount display
Incident level
display
Intercepted
amount display
±
4 V.
None of beam intercepted 4 V
Entire beam intercepted
None of beam intercepted −4 V
Entire beam intercepted
None of beam intercepted 20 mA
Entire beam intercepted
None of beam intercepted 4 mA
Entire beam intercepted
RUN
.
to
Section 1-6
−4 V
4 V
4 mA
20 mA
T
FUN
, and then
.
17