4-4-2 Operation Procedure for Setting Logic and OFF Delay Time

Procedure for setting logic and OFF delay time in this device is described below.
To stop setting logic and OFF delay time before Step 23 in the table below, turn the mode se-
lector switch to the "RUN" side, and the settings will be canceled. After Step 24 or later, the set-
tings cannot be canceled.
Step Status of indicators and switches
1
2
3
4
5
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Setting of Logics and OFF Delay Time
Mode selector switch: RUN side
Operation indicator (green): Lights up
The power saving function of this device turns OFF the 7-segment indicator
(red) 3 sec. after power ON, the end of initial diagnosis, or final operation.
Switch the mode selector switch to the "PROG" side.
This device transitions to "PROG mode."
The operator indicator (green) turns OFF.
The setting indicator (orange) blinks.
This device automatically transitions to "Indicator ON confirmation."
Individual segments of the 7-segment indicator (red) light up one by one.
Check for an error code displayed in the 7-segment indicator (red).
Press the rotary switch.
The setting indicator (orange) status changes from blinking to lighting up.
Press the rotary switch.
Transition to "Enter password."
Password selection indicator (orange) blinks.
Password 1 "
" is displayed in the the 7-segment indicator (red).
Enter password 1 and password 2.
At factory, password 1 is set to "
Description
", password 2, "
".
55