:SBUS<n>:FLEXray:TRIGger:EVENt:TYPE
Command Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:TYPE <event>
<event> ::= {WAKeup | TSS | {FES | DTS} | BSS}
Selects the FlexRay event to trigger on. The event setting is only valid
when the FlexRay trigger mode is set to EVENt.
• WAKeup — triggers on Wake- Up event.
• TSS — triggers on Transmission Start Sequence event.
• FES — triggers on either Frame End or Dynamic Trailing Sequence
• DTS — triggers on either Frame End or Dynamic Trailing Sequence
• BSS — triggers on Byte Start Sequence event.
Query Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:TYPE?
The :SBUS<n>:FLEXray:TRIGger:EVENt:TYPE? query returns the currently
selected FLEXray event.
Return Format
<event><NL>
<event> ::= {WAK | TSS | {FES | DTS} | BSS}
See Also
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
(see
page
1088)
event.