Sbus<N>:Flexray:trigger:event:bss:id - Agilent Technologies InfiniiVision 3000 Programmer's Manual

X-series
Hide thumbs Also See for InfiniiVision 3000:
Table of Contents

Advertisement

26
:SBUS<n> Commands
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID
Command Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID <frame_id>
<frame_id> ::= {ALL | <frame #>}
<frame #> ::= integer from 1-2047
The :SBUS<N>:FLEXray:TRIGger:EVENt:BSS:ID command sets the frame ID
used by the Byte Start Sequence (BSS) event trigger. This setting is only
valid if the trigger mode is EVENt and the EVENt:TYPE is BSS.
Query Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID?
The :SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID? query returns the current
frame ID setting for the Byte Start Sequence (BSS) event trigger setup.
Return Format
<frame_id><NL>
<frame_id> ::= {ALL | <frame #>}
<frame #> ::= integer from 1-2047
See Also
648
(see
page
1088)
"Introduction to :TRIGger Commands"
":SBUS<n>:FLEXray:TRIGger:EVENt:TYPE"
":SBUS<n>:FLEXray:TRIGger:EVENt:AUToset"
":TRIGger:MODE"
on page 851
":SBUS<n>:FLEXray:TRIGger"
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
on page 843
on page 649
on page 647
on page 645

Advertisement

Table of Contents
loading

Table of Contents