34
Obsolete and Discontinued Commands

:FUNCtion:VIEW

(see
page
1088)
Command Syntax
:FUNCtion:VIEW <view>
<view> ::= {{1 | ON} | (0 | OFF}}
The :FUNCtion:VIEW command turns the selected function on or off. When
ON is selected, the function performs as specified using the other
FUNCtion commands. When OFF is selected, function is neither calculated
nor displayed.
The :FUNCtion:VIEW command is provided for backward compatibility to previous
N O T E
oscilloscopes. Use the :FUNCtion:DISPlay command (see
page
317) instead.
Query Syntax
:FUNCtion:VIEW?
The :FUNCtion:VIEW? query returns the current state of the selected
function.
Return Format
<view><NL>
<view> ::= {1 | 0}
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide