20
:MEASure Power Commands
Table 91 :MEASure Power Commands Summary (continued)
Command
:MEASure:FACTor
[<source1>][,<source2
>] (see
page
455)
:MEASure:IPOWer (see
page
456)
:MEASure:OFFTime
[<source1>][,<source2
>] (see
page
457)
:MEASure:ONTime
[<source1>][,<source2
>] (see
page
458)
:MEASure:OPOWer (see
page
459)
:MEASure:PCURrent
[<source>] (see
page
460)
:MEASure:PLOSs
[<source>] (see
page
461)
:MEASure:REACtive
[<source1>][,<source2
>] (see
page
462)
448
Query
:MEASure:FACTor?
[<source1>][,<source2
>] (see
page
455)
:MEASure:IPOWer? (see
page
456)
:MEASure:OFFTime?
[<source1>][,<source2
>] (see
page
457)
:MEASure:ONTime?
[<source1>][,<source2
>] (see
page
458)
:MEASure:OPOWer? (see
page
459)
:MEASure:PCURrent?
[<source>] (see
page
460)
:MEASure:PLOSs?
[<source>] (see
page
461)
:MEASure:REACtive?
[<source1>][,<source2
>] (see
page
462)
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
Options and Query Returns
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the power
factor value in NR3 format
<return_value> ::= the input
power value in NR3 format
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the time in
seconds in NR3 format
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the time in
seconds in NR3 format
<return_value> ::= the output
power value in NR3 format
<source> ::= {CHANnel<n>|
FUNCtion | MATH | WMEMory<r>}
<n> ::= 1 to (# analog channels)
in NR1 format
<r> ::= 1-2 in NR1 format
<return_value> ::= the peak
current value in NR3 format
<source> ::= {CHANnel<n>|
FUNCtion | MATH | WMEMory<r>}
<n> ::= 1 to (# analog channels)
in NR1 format
<r> ::= 1-2 in NR1 format
<return_value> ::= the power loss
value in NR3 format
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the reactive
power value in NR3 format