:SBUS<n> Commands
:SBUS<n>:FLEXray:TRIGger:ERRor:TYPE
Command Syntax
:SBUS<n>:FLEXray:TRIGger:ERRor:TYPE <error_type>
<error_type> ::= {ALL | HCRC | FCRC}
Selects the FlexRay error type to trigger on. The error type setting is only
valid when the FlexRay trigger mode is set to ERRor.
• ALL — triggers on ALL errors.
• HCRC — triggers on only Header CRC errors.
• FCRC — triggers on only Frame CRC errors.
Query Syntax
:SBUS<n>:FLEXray:TRIGger:ERRor:TYPE?
The :SBUS<n>:FLEXray:TRIGger:ERRor:TYPE? query returns the currently
selected FLEXray error type.
Return Format
<error_type><NL>
<error_type> ::= {ALL | HCRC | FCRC}