:MEASure:OPOWer
Command Syntax
:MEASure:OPOWer
The :MEASure:OPOWer command installs an output power measurement on
screen.
Before sending this command or query, you must specify the channels
probing the input voltage, input current, output voltage, and output
current (using the :POWer:SIGNals:SOURce:VOLTage<i> and
:POWer:SIGNals:SOURce:CURRent<i> commands) and you must perform the
automated signals setup (using the :POWer:SIGNals:AUTosetup EFFiciency
command).
Query Syntax
:MEASure:OPOWer?
The :MEASure:OPOWer query returns the measured output power.
Return Format
<return_value><NL>
<return_value> ::= the output power value in NR3 format
See Also
•
•
•
•
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
(see
page
1088)
":POWer:SIGNals:SOURce:VOLTage<i>"
":POWer:SIGNals:SOURce:CURRent<i>"
":POWer:SIGNals:AUTosetup"
":POWer:EFFiciency:APPLy"
:MEASure Power Commands
on page 549
on page 548
on page 541
on page 512
20
459