SYMPTOM: VOICE
TERMINAL LIGHTS FLASH
WHEN AN AUTOMATIC
SYSTEM ACCESS
FEATURE IS ACTIVATED.
Possible Cause 2:
Control unit or voice terminal may be defective.
Do This
Step 1.
Program the feature on a
second voice terminal and try
to use the feature.
Step 2.
Replace the first voice
terminal with a voice
terminal known to be
working correct] y.
Possible Cause 1:
No lines are assigned to the ASA incoming or
outgoing line group.
Do This
Refer to Section 5,
"Reference" for instructions
for administering incoming
or outgoing lines for the
ASA feature you want.
Possible Cause 2:
Only one line is assigned to the incoming and outgoing group
and it's the same line for both.
Do This
Incoming and outgoing lines
cannot be the same line. See
Section 5 "Reference' for
instructions for
administering two
separate lines.
If
The feature works correctly
The feature still doesn't work
The trouble remains
The trouble no longer occurs
If
The feature works
The feature still doesn't work
If
The feature works
The feature still doesn't work
Troubleshooting Procedures
Then
The trouble is either the
voice terminal on which the
feature did not work or the
control unit. To determine
which, go to Step 2.
The problem is in the control
unit. Contact your
equipment supplier for
assistance.
The problem is in the control
unit. Contact your
equipment supplier for
assistance.
The first voice terminal is
defective. Replace it.
Then
Press the feature button twice
to stop the flashing light.
Go to Possible Cause 2.
Then
Press the feature button twice
to stop the flashing light.
Go to Possible Cause 3.
(continued)
7-11