Monitoring Poe Power Consumption (Cli Procedure) - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

CHAPTER 123
Verifying PoE Configuration
Monitoring PoE
Purpose
Action
Meaning
Copyright © 2010, Juniper Networks, Inc.
Monitoring PoE on page 3547
Monitoring PoE Power Consumption (CLI Procedure) on page 3548
Verifying PoE Configuration and Status (CLI Procedure) on page 3550
Use the monitoring functionality to view real-time data of the power consumed by each
PoE interface, and to enable and configure telemetry values. When telemetry is enabled,
the software measures the power consumed by each interface and stores the data for
future reference.
To monitor PoE using the J-Web interface, select
To monitor PoE power consumption with CLI commands in the CLI Terminal in the J-Web
interface:
Select
1.
Troubleshoot > CLI Terminal
Type a CLI command:
2.
show poe controller
show poe interface
show poe telemetries interface
For detailed information about using these CLI commands to monitor PoE power
consumption, see Monitoring PoE Power Consumption (CLI Procedure) in the EX Series
documentation at
http://www.juniper.net/techpubs
In the J-Web interface the PoE Monitoring screen is divided into two parts. The top half
of the screen displays real-time data of the power consumed by each interface and a
list of ports that utilize maximum power.
Select a particular interface to view a graph of the power consumed by the selected
interface.
The bottom half of the screen displays telemetry information for interfaces. The Telemetry
Status field displays whether telemetry has been enabled on the interface. Click the
Monitor > Power over Ethernet
.
.
.
3547