[edit]
user@switch2# show
protocols {
oam {
ethernet {
link-fault-management {
interface ge-0/0/1 {
negotiation-options {
allow-remote-loopback;
}
}
}
}
}
Verification
Verifying That OAM LFM Has Been Configured Properly
Verify that OAM LFM has been configured properly.
Use the
show oam ethernet link-fault-management
user@switch1#show oam ethernet link-fault-management
Interface: ge-0/0/0.0
Status: Running, Discovery state: Send Any
Peer address: 00:19:e2:50:3b:e1
Flags:Remote-Stable Remote-State-Valid Local-Stable 0x50
Remote entity information:
Remote MUX action: forwarding, Remote parser action: forwarding
Discovery mode: active, Unidirectional mode: unsupported
Remote loopback mode: supported, Link events: supported
Variable requests: unsupported
When the output displays the MAC address and the discover state is
that OAM LFM has been configured properly.
Configuring Ethernet OAM Link Fault Management (CLI Procedure) on page 4043
Understanding Ethernet OAM Link Fault Management for an EX Series Switch on
page 4039
Configuring Ethernet OAM Link Fault Management (CLI Procedure) on page 4043
Ethernet OAM link fault management (LFM) can be used for physical link-level fault
detection and management. The IEEE 802.3ah LFM works across point-to-point Ethernet
links either directly or through repeaters.