analyzer

Syntax
Hierarchy Level
Release Information
Description
Default
Options
Required Privilege
Level
Related
Documentation
3858
®
OS for EX Series Ethernet Switches, Release 10.4
analyzer {
name {
ratio number;
loss-priority priority;
input {
ingress {
interface (all | interface-name);
vlan (vlan-id | vlan-name);
}
egress {
interface (all | interface-name);
}
output {
interface interface-name;
vlan (vlan-id | vlan-name);
}
}
}
[edit ethernet-switching-options]
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Configure port mirroring. One analyzer (port mirroring configuration) can be configured
on an EX2200, EX3200, EX4200, or EX4500 switch and seven analyzers (port mirroring
configurations) can be configured on an EX8208 or EX8216 switch at a time. Other
analyzers can be present and disabled.
Port mirroring is disabled and Junos OS creates no default analyzers.
name
—Name that identifies the analyzer. The name can be up to 125 characters long,
must begin with a letter, and can include uppercase letters, lowercase letters,
numbers, dashes, and underscores. No other special characters are allowed.
The remaining statements are explained separately.
system—To view this statement in the configuration.
system-control—To add this statement to the configuration.
Example: Configuring Port Mirroring for Local Monitoring of Employee Resource Use
on EX Series Switches on page 3837
Example: Configuring Port Mirroring for Remote Monitoring of Employee Resource Use
on EX Series Switches on page 3842
Understanding Port Mirroring on EX Series Switches on page 3833
Copyright © 2010, Juniper Networks, Inc.