Table 532: SNMP Configuration Page (continued)
Field
Function
Rising Threshold
Specifies the value at which SNMP generates an event
(trap and system log message) when the value of a
sampled indicator is increasing.
For example, if the rising threshold is 90 (the default),
SNMP generates an event when the value of any key
indicator reaches or exceeds 90 percent.
Falling
Specifies the value at which SNMP generates an event
Threshold
(trap and system log message) when the value of a
sampled indicator is decreasing.
For example, if the falling threshold is 80 (the default),
SNMP generates an event when the value of any key
indicator falls back to 80 percent or less.
Related
Documentation

Configuration Statements for SNMP

[edit snmp] Configuration Statement Hierarchy

Related
Documentation
3902
®
OS for EX Series Ethernet Switches, Release 10.4
Monitoring System Process Information on page 654
Monitoring System Properties on page 650
[edit snmp] Configuration Statement Hierarchy on page 3902
snmp {
rmon {
history index {
bucket-size number;
interface interface-name;
interval seconds;
owner owner-name;
}
}
}
Configuring SNMP (J-Web Procedure) on page 3899
Junos OS Network Management Configuration Guide
Your Action
Enter a value from 0 through 100. The default
value is 90.
Enter a value from 0 through 100. The default
value is 80.
NOTE: The falling threshold value must be less
than the rising threshold value.
Copyright © 2010, Juniper Networks, Inc.