falling-threshold

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
Copyright © 2010, Juniper Networks, Inc.
falling-threshold percentage;
[edit snmp health-monitor]
Statement introduced in Junos OS Release 8.0.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
The lower threshold is expressed as a percentage of the maximum possible value for the
sampled variable. When the current sampled value is less than or equal to this threshold,
and the value at the last sampling interval is greater than this threshold, a single event
is generated. A single event is also generated if the first sample after this entry becomes
valid is less than or equal to this threshold. After a falling event is generated, another
falling event cannot be generated until the sampled value rises above this threshold and
reaches the
rising-threshold
—The lower threshold for the alarm entry.
percentage
Range:
through
1
100
Default:
percent of the maximum possible value
70
snmp—To view this statement in the configuration.
snmp-control—To add this statement to the configuration.
Configuring the Falling Threshold or Rising Threshold
rising-threshold on page 3935
.