Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual page 4110

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
Table 540: Performance Probe Tests Configuration Fields (continued)
Field
Destination Interface
Maximum Probe Thresholds
Successive Lost Probes
Lost Probes
Round Trip Time
Jitter
Standard Deviation
Egress Time
Ingress Time
Jitter Egress Time
Jitter Ingress Time
4006
®
OS for EX Series Ethernet Switches, Release 10.4
Function
Enables hardware timestamp on the
specified interface.
Sets the number of probes that can be
lost successively, if exceeded, triggers a
probe failure and generates a system log
message.
Sets the number of probes that can be
lost , if exceeded, triggers a probe failure
and generates a system log message.
Sets the round-trip time (in
microseconds), from the switch to the
remote server, if exceeded, triggers a
probe failure and generates a system log
message.
Sets the jitter (in microseconds), if
exceeded, triggers a probe failure and
generates a system log message.
Sets the maximum allowable standard
deviation (in microseconds), if exceeded,
triggers a probe failure and generates a
system log message.
Sets the one-way time (in
microseconds), from the switch to the
remote server, if exceeded, triggers a
probe failure and generates a system log
message.
Sets the one-way time (in
microseconds), from the remote server
to the switch, if exceeded, triggers a
probe failure and generates a system log
message.
Sets the outbound-time jitter (in
microseconds), if exceeded triggers a
probe failure and generates a system log
message.
Sets the inbound-time jitter (in
microseconds), if exceeded, triggers a
probe failure and generates a system log
message.
Your Action
Select an interface from the list.
Type a number from 0 through 15.
Type a number from 0 through 15.
Type a number from 0 through
60000000.
Type a number from 0 through
60000000.
Type a number from 0 through
60000000.
Type a number from 0 through
60000000.
Type a number from 0 through
60000000 (microseconds).
Type a number from 0 through
60000000.
Type a number from 0 and 60000000.