Serial port
n
peer: Any user that tries to open the port can change the port settings. All users that try
to open the port receive all of the data read to the port.
n
primary: Only the user that opened the port can change the port settings. All other
users that try to open the port receive all of the data read to the port.
6. Set the signal mode:
(config)> serial port1 signal mode value
(config)>
where value is one of:
Set the signaling interface type used on this serial port:
n
rs-232
n
rs-485
Enable termination if you want to enable electrical termination on this serial port:
l
The default is rs-232.
7. Set a label that will be used when referring to this port.
(config)> serial port1 label label
(config)>
8. (Optional) Set a label that will be used when referring to this port.
(config)> serial port1 label label
(config)>
9. Configure serial port logging:
a. Enable serial port logging:
(config)>serial port1 logging enable true
(config)>
b. Set the file name:
(config)>serial port1 logging filename string
(config)>
c. Set the maximum allowed log size for the serial port log when starting the log:
(config)>serial port1 logging size value
(config)>
where value is the size of the log file in bytes. The default is 65536.
d. Specify the data type:
(config)>serial port1 logging type value
(config)>
IX40 User Guide
Advanced RealPort configuration without using the Digi Navigator
(config)> serial port1 termination true
(config)>