Send Digital And Analog I/O Monitoring Information To Digi Remote Manager - Digi IX40 User Manual

Table of Contents

Advertisement

Digital Input/Output and Analog
Input
6. Set the protocol:
(config io monitoring server name )> protocol value
(config io monitoring server name )>
where value is either tcp or udp. tcp is the default.
7. Set the interval, in seconds, that the device will use to upload I/O information to the remote
server:
(config io monitoring server name )> polling_period int
(config io monitoring server name )>
The default is one second.
8. Repeat for each additional remote server.
9. Save the configuration and apply the change
(config io monitoring server name)> save
Configuration saved.
>
10. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Send digital and analog I/O monitoring information to Digi
Remote Manager
Required configuration items
n
One or more remote servers to send digital and/or analog I/O monitoring information to.
n
The port on the remote server that will listen for monitoring information.
Additional configuration items
The communication protocol (either TCP or UDP).
n
The polling period that the device will use to gather monitoring information.
n
É
Web
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
2. Access the device configuration:
Remote Manager:
a. Locate your device as described in
device.
b. Click the Device ID.
IX40 User Guide
Send digital and analog I/Omonitoring information to Digi Remote
Use Digi Remote Manager to view and manage your
Manager
842