Send Digital And Analog I/O Monitoring Information To A Remote Server - Digi IX40 User Manual

Table of Contents

Advertisement

Digital Input/Output and Analog Input
2. To calibrate the low and high ends of the analog input range for analog input ports:
a. To calibrate the low end of the analog input range for analog input port 1 (ain1):
> ain calibrate ain1 low int
>
where int is an integer representing the voltage in mV, or the current, in uA, that is
connected to the analog input.
b. To calibrate the high end of the analog input range for analog input port 1 (ain1):
> ain calibrate ain1 high int
>
where int is an integer representing the voltage in mV, or the current in uA, that is
connected to the analog input.
c. Repeat as necessary for analog inputs ain2, ain3, and ain4.
3. To rest the calibration:
a. To reset the calibration for ain1:
> ain calibration-reset ain1
4. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Send digital and analog I/O monitoring information to a remote
server
Required configuration items
One or more remote servers to send digital and/or analog I/O monitoring information to.
n
The port on the remote server that will listen for monitoring information.
n
Additional configuration items
n
The communication protocol (either TCP or UDP).
n
The polling period that the device will use to gather monitoring information.
É
Web
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
2. Access the device configuration:
Remote Manager:
a. Locate your device as described in
device.
IX40 User Guide
Send digital and analog I/Omonitoring information to a remote server
Use Digi Remote Manager to view and manage your
840