Digi IX40 User Manual page 601

Table of Contents

Advertisement

Services
n
IX40 User Guide
where value is any number between 10 milliseconds and one second, and take
the format number{ms|s}.
For example, to set idle_gap to 20 milliseconds, enter 20ms.
v. Set the amount of time to wait before disconnecting the socket when it has
become inactive:
(config service modbus_gateway client test_modbus_client)> inactivity_timeout
value
(config service modbus_gateway client test_modbus_client)>
where value is any number of minutes or seconds up to a maximum of 15
minutes, and takes the format number{m|s}.
For example, to set inactivity_timeout to ten minutes, enter either 10m or
600s:
(config service modbus_gateway client test_modbus_client)> inactivity_timeout
600s
(config service modbus_gateway client test_modbus_client)>
vi. Set the hostname or IP address of the remote host on which the Modbus server
is running:
(config service modbus_gateway client test_modbus_client)> remote_host ip_
address | hostname
(config service modbus_gateway client test_modbus_client)>
If connection_type is set to serial:
i. Set the serial port:
i. Use the ?to determine available serial ports:
(config service modbus_gateway client test_modbus_client)> ... serial port ?
Serial
Additional Configuration
-------------------------------------------------------------------------------
port1
(config service modbus_gateway client test_modbus_client)>
ii. Set the port:
(config service modbus_gateway client test_modbus_client)> serial port
(config service modbus_gateway client test_modbus_client)>
ii. Set the packet mode:
(config service modbus_gateway client test_modbus_client)> serial packet_mode
value
(config service modbus_gateway client test_modbus_client)>
Port 1