(config)>serial port1 autoconnect conn_type value
(config)>
where value is one of:
n
n
n
n
n
The default is tls.
d. Set the host name or IP address of the destination server:
(config)>serial port1 autoconnect destination hostname/IP_address
(config)>
When using SSH, this should be prefixed with the user name and followed by @, for
example:
(config)>serial port1 autoconnect destination admin@192.168.1.1
(config)>
e. Set the TCP port of the destination server:
(config)>serial port1 autoconnect port int
(config)>
where int is any integer between 1 and 65535.
f. To enable TCP keepalive:
(config)>serial port1 autoconnect keepalive true
(config)>
g. To enable TCP nodelay:
(config)>serial port1 autoconnect nodely true
(config)>
h. Set the text to be transmitted to the remote server when the socket connects:
(config)>serial port1 socketid string
(config)>
14. (Optional) Configure data framing:
a. Enable data framing:
(config)>serial port1 framing enable true
(config)