Serial port
7. Set the number of data bits used by the device to which you want to connect:
(config)>path-paramdatabits bits
(config)>
8. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity parity
(config)>
Allowed values are:
even
n
odd
n
none
n
The default is none.
9. Set the stop bits used by the device to which you want to connect:
(config)>path-paramstopbits bits
(config)>
10. Set the type of flow control used by the device to which you want to connect:
(config)>path-paramflow value
(config)>
where value is one of:
none
n
rts/cts
n
xon/xoff
n
11. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
12. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Configure Remote Access mode
Remote Access mode allows for remote access to another device that is connected to the serial port.
To change the configuration to match the serial configuration of the device to which you want to
connect:
Web
LR54 User Guide
Configure Remote Access mode