Serial port
For example, to set idle_timeout to ten minutes, enter either 10m or 600s:
(config)>serial port1 idle_timeout 600s
(config)
The default is 15m.
12. Configure monitor settings.
a. (Optional) Enable monitoring of CTS (Clear to Send) changes on this port:
(config)>serial port1 monitor cts true
(config)
b. (Optional) Enable monitoring of DCD (Data Carrier Detect) changes on this port:
(config)>serial port1 monitor dcd true
(config)
13. (Optional) Configure autoconnect:
a. Enable autoconnect:
(config)>serial port1 autoconnect enable true
(config)>
b. Set the option that will trigger the connection:
(config)>serial port1 autoconnect trigger value
(config)>
where value is one of:
n
n
n
n
n
n
The default is always.
c. Set the option that initiates the connection:
LR54 User Guide
always
data
dcd
destination
dsr
match
If match is selected:
i. Set the string that, when received, will trigger the connection:
(config)>serial port1 autoconnect match_string string
(config)>
ii. flush_string is enabled by default, which will discard the matched string from
data sent to the server. To disable:
(config)>serial port1 autoconnect flush_string false
(config)>