Serial port
esac
done
17. Click Apply to save the configuration and apply the change.
The Apply button is located at the top of the WebUI page. You may need to scroll to the top of
the page to locate it.
  Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the LR54
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. The serial port is enabled by default. To disable:
(config)> serial port1 enable false
(config)>
4. Set the mode:
(config)> serial port1 mode ppp_dialin
(config)>
5. (Optional) Set a label that will be used when referring to this port.
(config)> serial port1
(config)>
6. Set the baud rate used by the device to which you want to connect:
(config)> serial port1 baudrate rate
(config)>
7. Set the type of flow control used by the device to which you want to connect:
(config)> serial port1 flow value
(config)>
LR54 User Guide
label label
Configure PPP dial-in mode
237