5 Diagnosis Screens

5.8.3 Outputting Sampling Data

Sampling can be output on the data I/O screen under [Mainte] tag.
Operation method (Outputting the sampling data)
(1)
Select the data I/O screen under [Mainte] tag.
Select the menu [Area change] and select the menu
(2)
[Memory].
Select the menu [Dir] and select the menu [Smp
(3)
data].
Set the destination device, directory, file name in the
(4)
setting column B.
(5)
Press the menu [Trnsfr A->B].
(Note 1) The data can not be output when the sampling is not executed.
(Note 2) The data can be output only when the sampling output valid parameter (#1224 aux08/bit0) is valid.
(Note 3) The output format differs depending on the sampling parameter "Output form".
(Note 4) The header information is not added to output sampling data.
Output file format (when output in decimal figure)
Sampling data is output in decimal figure when the sampling parameter "Output form" is set to "0".
(Example) When the number of channel is 3, the address is 1 to 3, and the output unit is E,
it stops when 1ch is 100mm, 2ch is -100mm and 3ch is 50mm.
I - 328
1ch
1st data
200000000
2nd data
200000000
3rd data
200000000
:
:
"Memory" will display on A: Dev.
"Sampling data" will display on the directory and
"NCSAMP.CSV" will on the file name.
Sampling file will be output.
Output format
2ch
3ch
-200000000
100000000
-200000000
100000000
-200000000
100000000
:
: